SLIDING DOORS

Forster Fuego light
Fire- and smoke-resistant sliding door
El30_RS with increased tightness

Technical data

Material variants:
Galvanised steel, polished stainless steel on request

Dimensions:
Clear passageway, 1 leaf: 1380 × 2500 mm
Clear passageway, 2 leaf: 2600 × 2500 mm
Fixed glazing (W×H): unlimited × 5000 mm
Max. panel size 2000 × 3900 mm

Performance characteristics:

Heat transfer: Uf > 0.49 W / (m²K) mullion / transom
Ucw > 0.6 W / (m2K)
Resistance to wind load in accordance with EN 12179; 3 kN / m2, safety
glass 4.5 kN / m2
Watertightness in accordance with EN 12155: RE1350
Air permeability in accordance with EN 12153: AE (>600)
Impact resistance in accordance with EN 14019: I5 / E5
Sound insulation up to RW = 45 dB in accordance with EN ISO 140-3

System characteristics:

CE marking in accordance with EN 13830
Design variants: curtain wall or inner partition
Passive House certified
Easy installation thanks to mechanical T-joints
Cover strips in aluminium and stainless steel
Face widths: mullion / transom profile in 45 and 60 mm
Construction depth: 50–250 mm
Max. leaf weight: 500 kg
Max. filling element thickness: 70 mm
Glazing: dry glazing

Country-specific approvals and requirements observed

Forster Fuego light
Telescopic fire-resistant sliding door El30

Technical data

Material variants:
Galvanised steel

Dimensions:
Clear passageway, 1 leaf: 2200 × 3000 mm
Clear passageway, 2 leaf: 2600 × 3000 mm

Performance characteristics:

Heat transfer: Uf > 0.49 W / (m²K) mullion / transom
Ucw > 0.6 W / (m2K)
Resistance to wind load in accordance with EN 12179; 3 kN / m2, safety
glass 4.5 kN / m2
Watertightness in accordance with EN 12155: RE1350
Air permeability in accordance with EN 12153: AE (>600)
Impact resistance in accordance with EN 14019: I5 / E5
Sound insulation up to RW = 45 dB in accordance with EN ISO 140-3

System characteristics:

CE marking in accordance with EN 13830
Design variants: curtain wall or inner partition
Passive House certified
Easy installation thanks to mechanical T-joints
Cover strips in aluminium and stainless steel
Face widths: mullion / transom profile in 45 and 60 mm
Construction depth: 50–250 mm
Max. leaf weight: 500 kg
Max. filling element thickness: 70 mm
Glazing: dry glazing

Country-specific approvals and requirements observed